Ademco Vista-15P v1 Program Sheet
Ademco Vista-15P v1 Program Sheet

Version Info Sticker on main chip

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 600ma Aux output

2A Siren output

Device Address 00 5881 L/M/H Receiver or Receiver in 6128RF/6150RF Keypads

03 IP Internet or GSM Long Range Radio

04 4286 Voice Module

07 4219/4229 Zone Expander 1 (Zones 09 to 16, this address is not available if zone doubling)

08 4219/4229 Zone Expander 2 (Zones 17 to 24)

12 to 13 4204 Relay Expander (1st must be address 12)

16 to 23 6128/6139/6150/6160 Keypads (1st keypad must use address 16)

28 5800TM Module for Bi-Direction Keyfobs (cut Red W1 jumper)

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (16 to 23)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0"

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 16 then * to exit back to flashing " -- 0 0"

  5. Press * to exit

Addressing Tips 1. Connect 6160 or 6139 Alpha keypad to the panel, change the address to 23

2. Enter programming with 6150RF keypad, enter 10 in location *196

3. Exit programming and the 6139/6160 keypad will begin working, program rest of panel

4. When finished use 6150RF to go to location *196

5. Enter 00 to erase Alpha keypad from system and exit programming

(The 6160/6139 saves address settings so it can be used to program future Vista-15P's)

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

  1. = Enable

  1. = RF Jam Enabled

  1. = Quick Bypass User Code + 6 + # Enabled

  1. = Enable zone to chime in Zone List 3)

  1. = G 7 = H 8 = I 9 = J #10 = K #11 = L

#12 = M #13 = N #14 = O #15 = P

  1. st digit = 1 to 9

  2. nd digit = # + 11 = * or # + 12 = #

  1. = Enable

  1. = 1 alarm sound per per zone in an arming period

  1. = No Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

  1. = Enable

  1. = 1/2 second siren after exit delay expires

  2. = 1/2 second siren after RF arm command

  1. = Enable

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

(Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

I _ 7 _I Secondary 1 = 3/1, 4/1 Radionics Standard

2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All Reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

(For pager programming go to *160 - *171)

  1. = Enable

  1. = Sescoa

  1. to F x15 seconds (1 to 225 seconds)

If *54 is set at 0 then system will send on both the landline and radio/cellular/internet backup

If *54 is set at 2 and *55 is set at 0 then panel will send by landline and if it cannot connect

within 30 seconds it will also send by radio/cellular/internet backup

For radio/cellular only accounts set *54 to F and *55 to 1 to prevent signals using landline

  1. = Long Range Radio First

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) (* for next, # for previous menu)

Tech_201000000090.gif

Hardwire Sensors Zone 01 to 06

2-wire Smokes Zone 01 only

4-wire Smokes Zone 02 to 06 (Requires 4204/4229 Relay)

4219/4229 Zone Expander Zone 10 to 17

Keyfobs Zone 49 to 56

Wireless Zone 9 to 34 (Depends on receiver capacity)

Duress Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

3. This shows summary of current Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

4. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled/Deleted 12 = Monitor Zone (non Burg sends E150)

  1. = Delay Zone 14 = 24 Hr Carbon Monoxide

  2. = Secondary Delay Zone 16 = 24 Hr Fire w/ Verification

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

To delete Zone enter 00 06 = 24 Hr Silent/Holdup 23 = No Alarm Response

then * until "Delete Sensor" 07 = 24 Hr Police Panic 24 = Silent Burglary

08 = 24 Hr Aux/Medical 77 = Keyswitch Zone

09 = 24 Hr Supervised Fire 90 = Configurable Zone

10 = Interior with Delay 91 = Configurable Zone

(see locations 182 - 185)

User Assign 1. Exit programming

2. Add a user code to system (03 to 33), many techs use last 4 digits of keyfob serial number

3. Master Code + 8 + User (03 to 33) + # + 4

4. Enter 1st keyfob Zone (Example Zone 53) (Keypad should beep)

5. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (10 in first section gives report of A0)

5a. Enter Type of Zone (appears on Zones 2 to 6 only) (* for next, # for previous menu)

Tech_201000000339.gif 0 = EOL Resistors

1 = Normally Closed

2 = Normally Open

Tech_201000000340.gif

5b. Enter Speed of Zone (appears on Zones 1 to 6 only) (* for next, # for previous menu)

Tech_201000000189.gif 0 = 10msec

1 = 350msec (Default)

2 = 700msec

3 = 1.2 seconds

Hardwire Zones advance to step 9, Wireless Zones continue with step 6

6. Enter type of Sensor (* for next, # for previous menu)

Tech_201000000190.gif 2 = Auxiliary Wired (Zone Expander)

3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

7. Serial Number Programming (* for next, # for previous menu)

Press 1 then enter serial number or trip sensor twice, Loop number will also be learned

Tech_201000000173.gif This shows ready to learn

Tech_201000000174.gif Serial and Loop number is manually entered here

or learned by tripping twice (keypad will beep)

(Serial number sticker is on sensor)

8. If "Set to Confirm" was selected while first entering *56 this will appear

Tech_201000000191.gif Trip sensor again to confirm

Tech_201000000192.gif If incorrect serial number was learned this will appear

(This can be used to find out a serial number if sticker was removed)

9. This shows summary of new sensor programming (* for next, # for previous menu)

Tech_201000000099.gif

10. Press 0 for next sensor or 1 to enter Alpha descriptions

Tech_201000000100.gif

11. Enter next sensor or 00 to exit * menu

Tech_201000000090.gif

12. Press * or # to exit

Tech_201000000193.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

(If altering function keys A B or C delete programming for zones 95, 99 or 96)

Defaults

Function Key A Zone 95

Function Key B Zone 99

Function Key C Zone 96

Function Key D Single Button Page

1. Press Function Key to program (A = Top to D = Bottom Function Key)

Tech_201000000341.gif

2. Display shows Function Key chosen (* for next, # for previous menu)

Tech_201000000342.gif

3. Choose Function for this Key (* for next, # for previous menu)

Tech_201000000343.gif 00 = A Zone 95 B = Zone 99 C = Zone 96 D = Single Button Page

  1. = Single Button Page (sends 999-9999 message to Pager

  2. = Display Time

  3. = Arm Away

  4. = Arm Stay

  5. = Arm Night/Stay (any Zone in Zone List 5 *81 menu)

  6. = Step Arming (Stay then Night/Stay then Away)

  7. = Device A Activation (Type 66 Function in *80 menu)

08 = Communication Test

09 = Macro Key 1 (Activated by User Code + # + 66)

10 = Macro Key 2 (Activated by User Code + # + 66)

4. Enter next Function Key or 0 to exit

Tech_201000000344.gif

5. Press * or # to exit

Tech_201000000193.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) then *

Tech_201000000176.gif

3. Enter Zone Type (Display moves to Report Code, # starts over)

Tech_201000000177.gif 00 = Zone Disabled/Deleted 12 = Monitor Zone (non Burg sends E150)

  1. = Delay Zone 14 = 24 Hr Carbon Monoxide

  2. = Secondary Delay Zone 16 = 24 Hr Fire w/ Verification

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

To delete Zone enter 00 06 = 24 Hr Silent/Holdup 23 = No Alarm Response

then * until "Delete Sensor" 07 = 24 Hr Police Panic 24 = Silent Burglary

08 = 24 Hr Aux/Medical 77 = Keyswitch Zone

09 = 24 Hr Supervised Fire 90 & 91 = Configurable Zone

10 = Interior with Delay (see locations 182 - 185)

4. Display moves to Report Code, if needed enter 10 (Display moves to Sensor Type, # starts over)

Tech_201000000178.gif

A key moves right through fields if needed

B key moves left through fields if needed

C key copies previous Zone attributes

Hardwired Zones automatically skip to step 9, Wireless Zones continue with step 5

5. Enter Wireless sensor type then *

Tech_201000000179.gif 3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

6. If Wireless enter Serial Number or trip sensor twice (Keypad will beep twice as Sensor learns)

Tech_201000000180.gif

Tech_201000000181.gif

7. Enter Loop only if manually entering Serial Number (* for next, # for previous menu)

Tech_201000000182.gif

8. If "Set to Confirm" was selected while first entering *58 this will appear

Tech_201000000183.gif Trip sensor again to confirm

Tech_201000000184.gif This shows panel and sensor serials match

9. Enter next sensor or 00 to exit

Tech_201000000185.gif

10. Press * or # to exit

Tech_201000000193.gif

  1. = January 08 = August

  2. = February 09 = September

  3. = March #10 = October

  4. = April #11 = November

  5. = May #12 = December

  6. = June

I _ 5 _I End 2 = 2nd Weekend

3 = 3rd Weekend

4 = 4th Weekend

5 = Last Weekend

6 = Next to Last Weekend

  1. = 3rd from Last Weekend

    Tech_201000000345.gif

    Tech_201000000346.gif

    Tech_201000000347.gif

    Tech_201000000348.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Enter Zone List to program (* for next, 00 to exit)

Tech_201000000115.gif List 1 = General Purpose

List 2 = General Purpose

List 3 = Chime by Zone

List 4 = Cross Zones (see also *85 Cross Zone Timer)

List 5 = Night/Stay Arm (Enter all interior zones that will arm)

List 6 = General Purpose

List 7 = General Purpose

List 8 = General Purpose

List 9 = Zones that activate Pager 1

List 10 = Zones that activate Pager 2

2. Enter Zone(s) to add to Zone List

Tech_201000000116.gif Enter multiple Zones as 01* 02* 03*, finish with 00

3. Delete Zone List here if needed

Tech_201000000117.gif Enter multiple Zones as 01* 02* 03*, finish with 00

4. Delete Zone here if needed

Tech_201000000118.gif

Tech_201000000119.gif Delete multiple Zones as 01* 02* 03*, finish with 00

5. Enter next Zone List to program or 00 to exit

Tech_201000000115.gif

6. Press * or # to exit

Tech_201000000193.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

(RF arming overrides this feature) 1 = Enable

Set 2 zones in *81 Zone List 4 1 = 30 sec # + 10 = 6 min

if both zones activate in this time 3 = 60 sec # + 11 = 7 min

period alarm will be sent. 4 = 90 sec # + 12 = 8 min

5 = 2 min # + 13 = 10 min

If one zone goes into alarm a E380 6 = 2 1/2 min # + 14 = 12 min

trouble will be sent instead 7 = 3 min # + 15 = 15 min

  1. = 4 min

(Shows CA or CANCEL on display) 1 = Enable

  1. = 30 sec # + 10 = 6 min

3 = 60 sec # + 11 = 7 min

4 = 90 sec # + 12 = 8 min

5 = 2 min # + 13 = 10 min

6 = 2 1/2 min # + 14 = 12 min

7 = 3 min # + 15 = 15 min

8 = 4 min

(Add together if needed) 1 = Log Alarm/Alarm Restore

2 = Log Trouble/Trouble Restore

4 = Log Bypass/Bypass Restore

8 = Log Open/Close

F = Log All

  1. = AAV 2-Way Enable

8 = Enable Exit Delay Restart

# + 12 = AAV + Exit Delay Restart

  1. = Disable

  2. to 15# = 1 to 15 min before Alarm

  3. nd Digit

0 = Keypad Display on Phone Fault

  1. = Keypad Display + Sounder

  2. = Keypad Display/Sounder/

Program Output Start

  1. = 1 Report

  2. = 2 Reports

  1. to 14 = Rings before answer

15 = Answering Machine over-ride

Pager Information

  1. Enter Pager number in *160

  2. Enter Pager characteristics in *161 if needed (if Pin Numbers or Access Codes are required)

  3. Enter what pager reports in *162

  4. Enter Pager delay in *172 (Leave at 3 minutes)

  5. If needed disable Pager O/C reports - Master Code + 8 + User + #5 + 0 (by default paging is enabled)

  6. If needed enable "D" Key (bottom Function Key) for 1-button page in *57

  7. If sending Zone Alarms add which Zones will activate pager (01 to 99) to Zone List 9 in *81

  8. Report codes in *65 and *66 are NOT required

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

  1. = Open/Close All Users

4 = All Alarms & Troubles

5 = Alarms/Troubles/Open/Close

# + 12 = Alarms/Troubles in Zone List 9

# + 13 = Alarms/Troubles in Zone List 9

Open/Close for All Users

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

  1. = Open/Close All Users

4 = All Alarms & Troubles

5 = Alarms/Troubles/Open/Close

# + 12 = Alarms/Troubles in Zone List 10

# + 13 = Alarms/Troubles in Zone List 10

Open/Close for All Users

1 = 1 minute

2 = 2 minutes

3 = 3 minutes

  1. = Enabled (for certain ESL 2-wire smoke detectors)

(Outputs/Relays) I _ 0 _I 1 = 30 sec # + 10 = 6 min

3 = 60 sec # + 11 = 7 min

4 = 90 sec # + 12 = 8 min

5 = 2 min # + 13 = 10 min

6 = 2 1/2 min # + 14 = 12 min

7 = 3 min # + 15 = 15 min

8 = 4 min

  1. = 50 Hz

I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I

  1. Enter each digit of report code

  2. * scrolls forward 1 digit, # scrolls back back 1 digit

  3. After last digit * exits

Use fields 182 and/or 184 to create a special zone type for *56

Use fields 183 and/or 184 to set a Contact ID report code for alarm and trouble of that zone type

Example: For waterbug sensor enter 8 2 4 #13 4 1 4 0 6 2 in *182 and enter alarm report code of 154, trouble 370 in *183

Many 24 hour zones can use the above programming with different alarm and trouble report codes

I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I

  1. = Keypad Disabled

  1. = No Sound Suppression

  1. = Suppress Chime Beeps only

  1. to 5 = Seconds between Updates

  1. = 2-Digit Fixed trouble "91"

Schedules (Alpha keypads only)

  1. Enter with Master or Installer Code + # + 64

(Master Code can program Schedules 01 to 04, Installer can program 01 to 08)

  1. Select Schedule to program then *

    Tech_201000000326.gif
(01 to 08 or 00 to exit)

  1. Enter Event you want to occur then *

    Tech_201000000327.gif
(00 to 11)

00 = Clear Event (Deletes programmed event)

  1. = Relay On/Off

  2. = User Access

  3. = Latch Key Report to Pager

  4. = Forced Stay Arming

  5. = Forced Away Arming

  6. = Auto Disarm

  7. = Display "Reminder"

10 = Display Custom Words 8, 9 and 10*

11 = Periodic Test Report*

*These options accessable with Installer Code only

3a. if 01 was selected this screen appears, enter Device then *

Tech_201000000328.gif (00 to 18)

3b. if 02 was selected this screen appears, enter group then *

Tech_201000000329.gif (1 to 8)

4. Enter START Time & Days of Week

Tech_201000000330.gif

Example: For a STOP time of 12:30 PM Tuesday

Enter 12 30 then 1 for PM (0 if AM)

Then press * until cursor is under T (Tuesday) then 1 to select, 0 de-selects

Press * until display moves to next screen

5. Enter STOP Time & Days of Week

Tech_201000000331.gif

Example: For a STOP time of 06:15 AM Saturday

Enter 06 15 then 0 for AM (1 if PM)

Then press * until cursor is under S (Saturday) then 1 to select, 0 de-selects

Press * until display moves to next screen

6. Select if is a one time only Schedule or if it repeats then *

Tech_201000000332.gif 0 = Do not repeat/One time only

  1. = Repeat schedule weekly

  2. = Repeat schedule every other week (Biweekly)

  3. = Repeat schedule every third week

  4. = Repeat schedule every fourth week

7. Enter if schedule will be random, keypad will exit programming

(Example if schedule is set for 6:15 event will happen between 6:00 and 6:59)

Tech_201000000333.gif 0 = No

  1. = Yes

To program monthly test signal

  1. Enter Installer Code + # + 64

  2. Select schedule 11

  3. Enter START Time of 0230 AM then select 1 under which Day of Week

  4. Do not select a STOP event

  5. Select 4 under REPEAT OPTION for every fourth week

  6. Enter 1 at RANDOMIZE to allow test signal within a 1 hour time frame