Ademco Vista-20P v2 Program Sheet
Ademco Vista-20P v2/v3 Program Sheet

Version Info Sticker on main chip

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 00)

or

2. Power down then back up and press * and # within 1 minute

Move to Location * + Location

View Location # + Location (Display will read off one digit at a time)

Exit Program 1. *98 exits and does not allow re-entry to programming without cycling power and pressing * and #

or

2. *99 exits and does allow re-entry by Installer Code + 8 + 00

Programming can be re-entered up to 1 minute after exiting with * and # (# + 0 disables this feature)

Default Panel *97

Compatibility

Power Ratings 600ma Aux output

2A Siren output

Device Address 00 5881 L/M/H Receiver or Receiver in 6128RF/6150RF Keypads

  1. AUI Graphics Keypad 1

  2. AUI Graphics Keypad 2

  3. IP Internet or GSM Long Range Radio

  4. 4286 Voice Module

  5. AUI Graphics Keypad 3

  6. AUI Graphics Keypad 4

  7. 4219/4229 Zone Expander 1 (Zones 09 to 16, this address is not available if zone doubling)

08 4219/4229 Zone Expander 2 (Zones 17 to 24)

09 4219/4229 Zone Expander 3 (Zones 25 to 32)

10 4219/4229 Zone Expander 4 (Zones 33 to 40)

11 4219/4229 Zone Expander 5 (Zones 41 to 48)

12 to 15 4204 Relay Expander (1st must be address 12)

16 to 23 6128/6139/6150/6160 Keypads (1st keypad must use address 16)

28 5800TM Module for Bi-Direction Keyfobs (cut Red W1 jumper)

Keypad Address (6128/6139/6150/6160 keypads)

  1. Remove power from keypad then power back up

  2. Hold 1 & 3 for 3 seconds, "ADDR = XX" or "XX" should appear (XX = current address)

  3. Within 10 seconds enter 00 to erase old address then enter new address (16 to 23)

  4. Press * to save and exit

(6150RF keypads)

  1. Power keypad down then back up or remove backplate

  2. Within 30 seconds hold 1 & 3 for 3 seconds until flashing " - - 0 0"

  3. Press 1 and "cA XX" should appear (XX = current address)

  4. Press 16 then * to exit back to flashing " -- 0 0"

  5. Press * to exit

Addressing Tips 1. Connect 6160 or 6139 Alpha keypad to the panel, change the address to 23

2. Enter programming with 6150RF keypad, enter 10 in location *196

3. Exit programming and the 6139/6160 keypad will begin working, program rest of panel

4. When finished use 6150RF to go to location *196

5. Enter 00 to erase Alpha keypad from system and exit programming

Sniffer Test (Tests wireless sensors)

  1. Installer Code + # + 3

  2. Keypad displays all wireless sensors, faulting sensor removes it from list

  3. Exit with Installer Code + 1 (OFF)

Go-No Go Test (Verifies adequate RF by reducing receiver signal strength by 50%)

  1. Installer Code + # + 4

  2. a. Siren sounds

b. Panel may send walk test signal (If test signal was programmed)

c. "dd" appears on screen

d. Keypad will beep every 15 seconds

  1. Fault sensor, keypad should beep 3 times and display zone number,

if no beeps sound reorient or move sensor a few inches and try again

  1. Exit with Installer Code + 1 (OFF)

Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15

I _ 1 _I Partition 2 1 = Enable

  1. = RF Jam Detection Enabled

I _ 0 _I Partition 2 1 = Quick Bypass User Code + 6 + # Enabled

I _ 0 _I _ 0 _I Partition 2

I _ 0 _I _ 0 _I Common Lobby

  1. = Program Zones to chime in Zone List 3

  1. = G 7 = H 8 = I 9 = J #10 = K #11 = L

#12 = M #13 = N #14 = O #15 = P

  1. st digit = 1 to 9

  2. nd digit = # + 11 = * or # + 12 = #

  1. = Enable

  1. = 1 alarm sound per zone in an arming period

  1. = No Timeout

  1. = 4 minutes

  2. = 8 minutes

  3. = 12 minutes

  4. = 16 minutes

I _ 6 _I _ 0 _I Part 2 97 = 120 seconds

I _ 4 _I _ 5 _I Part 2 97 = 120 seconds

98 = 180 seconds

99 = 240 seconds

I _ 9 _I _ 0 _I Part 2 97 = 120 seconds

98 = 180 seconds

99 = 240 seconds

I _ 1 _I Partition 2 1 = Enable

(This sounds AFTER panel arms) I _ 0 _I Partition 2 1 = 1/2 second siren after exit delay expires

2 = 1/2 second siren after RF arm command

  1. = Enable

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

Partition 1 (Hex B = #+11 C = #+12 D = #+13 E = #+14 F = #+15)

Partition 1

Partition 2

Partition 2

  1. = DTMF Dial

  2. = Pulse Dial, CS on Watts Line

  3. = DTMF Dial, CS on Watts Line

I _ 7 _I Secondary 1 = 3/1, 4/1 Radionics Standard

2 = 4/2 Ademco L/S Standard

3 = 4/2 Radionics Standard

5 = 10-Digit Contact ID

6 = 4/2 Ademco Express

7 = Contact ID

8 = 3/1, 4/1 Ademco L/S Expanded

9 = 3/1, 4/1 Radionics Expanded

To Primary Phone To Secondary Phone

0 = All Reports Backup Only

  1. = Alarms, Restore, Cancel All Other Reports

  2. = All Reports except Open/Close, Test Open/Close, Test

  3. = Alarms, Restore, Cancel All Reports

  4. = All Reports except Open/Close, Test All Reports

  5. = All Reports (Dual Reporting) All Reports

(For pager programming go to *160 - *171)

  1. = 15 Seconds

  2. = 30 Seconds (Default)

  3. = 45 Seconds

  1. = Sescoa

  1. to F x15 seconds (1 to 225 seconds)

If *54 is set at 0 then system will send on both the landline and radio/cellular/internet backup

If *54 is set at 2 and *55 is set at 0 then panel will send by landline and if it cannot connect

within 30 seconds it will also send by radio/cellular/internet backup

For radio/cellular only accounts set *54 to F and *55 to 1 to prevent signals using landline

  1. = Long Range Radio First

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) (* for next, # for previous menu)

Tech_201000000090.gif This example shows Zone 10

Hardwire Sensors Zones 01 to 06

2-wire Smokes Zone 01 only

  1. wire Smokes Zones 02 to 06

4219/4229 Zone Expander Zones 10 to 48

Keyfobs Zones 49 to 64

Wireless Zones 09 to 48

Duress Zone 92

Fire Panic Zone 95

Medical Panic Zone 96

Police Panic Zone 99

3. This shows summary of current Zone programming (* for next, # for previous menu)

Tech_201000000091.gif

4. Enter Zone Type (* for next, # for previous menu)

Tech_201000000092.gif 00 = Zone Disabled/Deleted 12 = Monitor Zone (non Burg sends E150)

  1. = Delay Zone 14 = 24 Hr Carbon Monoxide

  2. = Secondary Delay Zone 16 = 24 Hr Fire w/ Verification

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

To delete Zone enter 00 06 = 24 Hr Silent/Holdup 23 = No Alarm Response

then * until "Delete Sensor" 07 = 24 Hr Police Panic 24 = Silent Burglary

08 = 24 Hr Aux/Medical 77 = Keyswitch Zone

09 = 24 Hr Supervised Fire 81 = AAV Monitor Zone

10 = Interior with Delay 90 = Configurable Zone

91 = Configurable Zone

(see locations 182 - 185)

Keyfobs will NOT operate until assigned to a User number

User Assign 1. Exit programming

2. Add a user code to system (03 to 49), many techs use last 4 digits of keyfob serial number

3. Master Code + 8 + User (03 to 49) + # + 4

4. Enter 1st keyfob Zone (Example Zone 53) (Keypad should beep)

5. Enter Partition of Zone (* for next, # for previous menu)

Tech_201000000093.gif 1 = Partition 1

2 = Partition 2

3 = Partition 3 (Common Lobby)

• The common zone sounds and reports alarms only when both partitions are armed. If only one

partition is armed, the system ignores faults on the common zone.

• Either partition may arm its system if the common zone is faulted, but once armed, the other

partition will not be able to arm unless the common zone is first bypassed or the fault is corrected.

• Faults on the common zone are displayed on common zone keypads, and will also appear on

another partition's keypad when that partition is armed.

• Either partition can clear and restore the common zone after an alarm.

6. Enter Report Code (* for next, # for previous menu)

Tech_201000000094.gif (10 in first section gives report of A0)

6a. Enter Type of Zone (appears on Zones 2 to 8 only) (* for next, # for previous menu)

Tech_201000000339.gif 0 = EOL Resistors

(appears if Zones 2 to 8) 1 = Normally Closed

2 = Normally Open

3 = Zone Doubling

4 = Double-Balance Zone

Tech_201000000367.gif

6b. Enter Speed of Zone (appears on Zones 1 to 8 only) (* for next, # for previous menu)

Tech_201000000189.gif 0 = 10msec

(Hardwire Zones only) 1 = 350msec (Default)

2 = 700msec

3 = 1.2 seconds

Hardwire Zones advance to step 10, Wireless Zones continue with step 8

7. Enter type of Sensor (* for next, # for previous menu)

Tech_201000000190.gif 2 = Auxiliary Wired (Expander)

3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

8. Serial Number Programming (* for next, # for previous menu)

Press 1 then enter serial number or trip sensor twice, Loop number will also be learned

Tech_201000000173.gif This shows ready to learn

Tech_201000000174.gif Serial and Loop number is manually entered here

or learned by tripping twice (keypad will beep)

(Serial number sticker is on sensor)

9. If "Set to Confirm" was selected while first entering *56 this will appear

Tech_201000000191.gif Trip sensor again to confirm

If incorrect serial number was learned this will appear

Tech_201000000192.gif

(This can be used to find out a serial number if sticker was removed)

10. This shows summary of new sensor programming (* for next, # for previous menu)

Tech_201000000099.gif

11. Press 0 for next sensor or 1 to enter Alpha descriptions

Tech_201000000100.gif

12. Enter next sensor or 00 to exit

Tech_201000000090.gif

13. Press * or # to exit

Tech_201000000193.gif

(If altering function keys A B or C delete programming for zones 95, 99 or 96)

Defaults

Function Key A Zone 95

Function Key B Zone 99

Function Key C Zone 96

Function Key D Single Button Page

1. Press Function Key to program (A = Top to D = Bottom Function Key)

Tech_201000000341.gif

2. Display shows Function Key chosen (* for next, # for previous menu)

Tech_201000000342.gif

3. Enter Partition of Function Key (* for next, # for previous menu)

Tech_201000000368.gif 1 = Partition 1

2 = Partition 2

3 = Common Partition (Lobby)

4. Choose Function for this Key (* for next, # for previous menu)

Tech_201000000343.gif 00 = A Zone 95 B = Zone 99 C = Zone 96 D = Single Button Page

  1. = Single Button Page (sends 999-9999 message to Pager

  2. = Display Time

  3. = Arm Away

  4. = Arm Stay

  5. = Arm Night/Stay (any Zone in Zone List 5 *81 menu)

  6. = Step Arming (Stay then Night/Stay then Away)

  7. = Device A Activation (Type 66 Function in *80 menu)

08 = Communication Test

09 = Macro Key 1 (Activated by User Code + # + 66)

10 = Macro Key 2 (Activated by User Code + # + 66)

11 = Macro Key 3 (Activated by User Code + # + 66)

12 = Macro Key 4 (Activated by User Code + # + 66)

5. Enter next Function Key or 0 to exit

Tech_201000000344.gif

6. Press * or # to exit

Tech_201000000193.gif

1. Press 1 here to allow confirming sensor after serial number input

Tech_201000000170.gif

2. Enter Zone to program (01 to 99) then *

Tech_201000000369.gif

3. Enter Zone Type (Display moves to Partitioning, # starts over)

Tech_201000000370.gif 00 = Zone Disabled/Deleted 12 = Monitor Zone (non Burg sends E150)

  1. = Delay Zone 14 = 24 Hr Carbon Monoxide

  2. = Secondary Delay Zone 16 = 24 Hr Fire w/ Verification

  3. = Perimeter/Instant 20 = Arm-Stay (RF only)

  4. = Interior Follower/Motions 21 = Arm-Away (RF only)

  5. = Trouble by Day/Alarm by Night 22 = Disarm (RF only)

To delete Zone enter 00 06 = 24 Hr Silent/Holdup 23 = No Alarm Response

then * until "Delete Sensor" 07 = 24 Hr Police Panic 24 = Silent Burglary

08 = 24 Hr Aux/Medical 77 = Keyswitch Zone

09 = 24 Hr Supervised Fire 81 = AAV Monitor Zone

10 = Interior with Delay 90 to 93 = Configurable

(see locations 182 - 185)

4. Display moves to Partition (Display moves to Report Code, # moves back)

Tech_201000000371.gif 1 = Partition 1

2 = Partition 2

3 = Common Partition (Lobby)

5. Display moves to Report Code, if needed enter 10 (Display moves to Sensor Type, # starts over)

Tech_201000000372.gif

A key moves right through fields if needed

B key moves left through fields if needed

C key copies previous Zone attributes

Hardwired Zones automatically skip to step 9, Wireless Zones continue with step 5

6. Enter Wireless sensor type then *

Tech_201000000373.gif 3 = Supervised RF (Doors, Motions, Smokes)

4 = Un-Supervised RF (some Panics)

5 = RF Button Type RF (Keyfobs/Panics)

7. If Wireless enter Serial Number or trip sensor twice (Keypad will beep twice as Sensor learns)

Tech_201000000180.gif

Tech_201000000181.gif

8. Enter Loop only if manually entering Serial Number (* for next, # for previous menu)

Tech_201000000374.gif

9. If "Set to Confirm" was selected while first entering *58 this will appear

Tech_201000000183.gif Trip sensor again to confirm

Tech_201000000184.gif This shows panel and sensor serials match

10. Enter next sensor or 00 to exit

Tech_201000000375.gif

11. Press * or # to exit

Tech_201000000193.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Installer Code + # + 0 + 0 sends Test report every 24 hours

Installer Code + # + 0 + 1 sends Test report every 1 week

Installer Code + # + 0 + 2 sends Test report every 28 days

I _ 0 _I Partition 2

I _ 0 _I Common Lobby

I _ 0 _I / I _ 0 _I Partition 2

I _ 0 _I / I _ 0 _I Common Lobby

  1. = January 08 = August

  2. = February 09 = September

  3. = March #10 = October

  4. = April #11 = November

  5. = May #12 = December

  6. = June

I _ 5 _I End 2 = 2nd Weekend

3 = 3rd Weekend

4 = 4th Weekend

5 = Last Weekend

6 = Next to Last Weekend

  1. = 3rd from Last Weekend

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Tech_201000000382.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Tech_201000000377.gif

Tech_201000000383.gif

Tech_201000000379.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1. Enter Zone List to program (* for next, 00 to exit)

Tech_201000000115.gif List 1 = General Purpose

List 2 = General Purpose

List 3 = Chime by Zone

List 4 = Cross Zones (see *85 Cross Zone Timer)

List 5 = Night/Stay Arm (Enter all interior zones that will arm)

List 6 = General Purpose

List 7 = General Purpose

List 8 = General Purpose

List 9 = Zones that activate Pager 1

List 10 = Zones that activate Pager 2

List 11 = Zones that activate Pager 3

List 12 = Zones that activate Pager 4

2. Enter Zone(s) to add to Zone List

Tech_201000000116.gif Enter multiple Zones as 01* 02* 03*, finish with 00

3. Delete Zone List here if needed

Tech_201000000117.gif Enter multiple Zones as 01* 02* 03*, finish with 00

4. Delete Zone here if needed

Tech_201000000118.gif

Tech_201000000119.gif Delete multiple Zones as 01* 02* 03*, finish with 00

5. Enter next Zone List to program or 00 to exit

Tech_201000000115.gif

6. Press * or # to exit

Tech_201000000193.gif

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

(RF arming overrides this feature) 1 = Partition 1

2 = Partition 2

3 = Both Partitions

Set 2 zones in *81 Zone List 4 1 = 30 sec # + 10 = 6 min

if both zones activate in this time 3 = 60 sec # + 11 = 7 min

period alarm will be sent. 4 = 90 sec # + 12 = 8 min

5 = 2 min # + 13 = 10 min

If one zone goes into alarm a E380 6 = 2 1/2 min # + 14 = 12 min

trouble will be sent instead 7 = 3 min # + 15 = 15 min

  1. = 4 min

  1. = Display CA or CANCEL after alarm

(Used with Configurable Zones) 1 = 30 sec # + 10 = 6 min

3 = 60 sec # + 11 = 7 min

4 = 90 sec # + 12 = 8 min

5 = 2 min # + 13 = 10 min

6 = 2 1/2 min # + 14 = 12 min

7 = 3 min # + 15 = 15 min

8 = 4 min

  1. = Lockout * & # after *98

(Installer Code is still enabled)

2 = Not Used

3 = Lockout all Local Program after *98

(Add together if needed) 1 = Log Alarm/Alarm Restore

2 = Log Trouble/Trouble Restore

4 = Log Bypass/Bypass Restore

8 = Log Open/Close

F = Log All

  1. = AAV 2-Way Enable

8 = Enable Exit Delay Restart

# + 12 = AAV + Exit Delay Restart

  1. = Disable

  2. to #15 = 1 to 15 min before Alarm

  3. nd Digit

0 = Keypad Display on Phone Fault

  1. = Keypad Display + Sounder

  2. = Keypad Display/Sounder/

Program Output Start

  1. = 1 Report

  2. = 2 Reports

  1. to 14 = Rings before answer

15 = Answering Machine over-ride

Pager Information

  1. Enter Pager number in *160

  2. Enter Pager characteristics in *161 if needed (if Pin Numbers or Access Codes are required)

  3. Enter what pager reports in *162

  4. Enter Pager delay in *172 (Leave at 3 minutes)

  5. If needed disable Pager O/C reports - Master Code + 8 + User + #5 + 0 (by default paging is enabled)

  6. If needed enable "D" Key (bottom Function Key) for 1-button page in *57

  7. If sending Zone Alarms add which Zones will activate pager (01 to 99) to Zone List 9 in *81

  8. Report codes in *65 and *66 are NOT required

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

  1. = Open/Close All Users

4 = All Alarms & Troubles

5 = Alarms/Troubles/Open/Close

# + 12 = Alarms/Troubles in Zone List 9

# + 13 = Alarms/Troubles in Zone List 9

Open/Close for All Users

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause

1 = 1 minute

2 = 2 minutes

3 = 3 minutes

  1. = Enabled (for certain ESL 2-wire smoke detectors)

(Outputs/Relays) I _ 0 _I 1 = 30 sec # + 10 = 6 min

3 = 60 sec # + 11 = 7 min

4 = 90 sec # + 12 = 8 min

5 = 2 min # + 13 = 10 min

6 = 2 1/2 min # + 14 = 12 min

7 = 3 min # + 15 = 15 min

8 = 4 min

  1. = 50 Hz

I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I

  1. Enter each digit of report code

  2. * scrolls forward 1 digit, # scrolls back back 1 digit

  3. After last digit * exits

Use fields 182 and/or 184 to create a special zone type for *56

Use fields 183 and/or 184 to set a Contact ID report code for alarm and trouble of that zone type

Example: For waterbug sensor enter 8 2 4 #13 4 1 4 0 6 2 in *182 and enter alarm report code of 154, trouble 370 in *183

Many 24 hour zones can use the above programming with different alarm and trouble report codes

I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I

I _ 0 _I ECP/AUI 2 1 = Partition 1

I _ 0 _I ECP/AUI 3 2 = Partition 2

I _ 0 _I ECP/AUI 4 3 = Common Lobby

Note: ECP address 3 and 4 only available on Vista-20PMT v3 and Vista-20PI panels

  1. = Partition 1

  1. = Partition 3 (Common Lobby)

  1. nd Digit

  1. = Supress Arming & E/E Beeps

  1. = Supress Arming & E/E Beeps

  1. to 5 = Seconds between Updates

  1. = Display Partition in upper left corner

  1. = 2-Digit Fixed trouble "91"

Schedules 1. Enter with Master or Installer Code + # + 64

(Alpha Keypad) (Master Code can program Schedules 01 to 16, Installer can program 17 to 32)

2. Select Schedule to program then *

Tech_201000000326.gif (01 to 32 or 00 to exit)

3. Enter Event you want to occur then *

Tech_201000000327.gif (00 to 11)

00 = Clear Event (Deletes programmed event)

  1. = Relay On/Off

  2. = User Access (Allow Arming and Disarming)

  3. = Latch Key Report to Pager

  4. = Forced Stay Arming

  5. = Forced Away Arming

  6. = Auto Disarm

  7. = Display "Reminder"

10 = Display Custom Words 8, 9 and 10*

11 = Periodic Test Report*

*These options accessable with Installer Code only

3a. if 01 was selected this screen appears, enter Device then *

Tech_201000000328.gif (00 to 18)

3b. if 02 was selected this screen appears, enter group then *

Tech_201000000329.gif (1 to 8)

Assign User Group Master Code + 8 + User (02 to 49) + Group (1 to 8)

4. Enter Partition then *

Tech_201000000360.gif 0 = All Partitions

  1. = Partition 1

  2. = Partition 2

  3. = Common Lobby Partition

5. Enter START Time & Days of Week

Tech_201000000330.gif

Example: For a START time of 12:30 PM Tuesday

Enter 12 30 then 1 for PM (0 if AM)

Then press * until cursor is under T (Tuesday) then 1 to select, 0 de-selects

Press * until display moves to next screen

6. Enter STOP Time & Days of Week

Tech_201000000331.gif

Example: For a STOP time of 06:15 AM Saturday

Enter 06 15 then 0 for AM (1 if PM)

Then press * until cursor is under S (Saturday) then 1 to select, 0 de-selects

Press * until display moves to next screen

7. Select if is is a one time only Schedule or if it repeats then *

Tech_201000000332.gif 0 = Do not repeat/One time only

  1. = Repeat schedule weekly

  2. = Repeat schedule every other week (Biweekly)

  3. = Repeat schedule every third week

  4. = Repeat schedule every fourth week

8. Enter if schedule will be random, keypad will exit programming

(Example if shedule is set for 6:15 event will happen between 6:00 and 6:59)

Tech_201000000333.gif 0 = No

  1. = Yes

9. Select next Schedule to program or 00 then * to exit

Tech_201000000326.gif (01 to 32 or 00 to exit)

To program monthly test signal

  1. Enter Installer Code + # + 64

  2. Select schedule 11

  3. Enter START Time of 0230 AM then select 1 under which Day of Week

  4. Do not select a STOP event

  5. Select 4 under REPEAT OPTION for every fourth week

  6. Enter 1 at RANDOMIZE to allow test signal within a 1 hour time frame